Digi-Sense™ Mini Particle Counter with Bluetooth™ Connectivity
View, store, and share real-time data on a smartphone
Beckman Coulter Multisizer™ 4e Smart Technology Aperture Tubes
Smart Technology Aperture Tubes are designed specifically for the Multisizer 4 or 4e Analyzer. The aperture allows extended sizing measurement range of 2% to 80% of the aperture diameter.
For Use With (Equipment) | Multisizer™ 4 or 4e Coulter Counters |
---|---|
Product Type | Aperature Tube |
Material | Glass |
Beckman Coulter LS 13 320 XR Multiwavelength (MW) Laser Diffraction Particle Size Analyzer
Multiwavelength Particle Size Analyzer incorporates PIDS to provide a dynamic range down to 0.010 μm. The DPS is capable of measuring dry powder samples, while the ULM analyzes samples suspended in aqueous or non-aqueous dilutents.
For Use With (Equipment) | Requires Controller, and Standard LS/HiCap Vacuum Unit |
---|---|
Model | LS 13 320 XR MW |
For Use With (Application) | Particle Size Analysis of Dry Powder, Aqueous, and Non-Aqueous Samples |
Beckman Coulter Multisizer™ 4e Coulter Counter
The Multisizer 4e Coulter Counter uses the Coulter Principle to detect particles via electrical zone sensing, regardless of the particle’s nature or optical properties. Therefore, the Coulter Counter is an ideal tool for detecting and counting a wide variety of particles.
Height (Metric) | 50.8 cm |
---|---|
Width (English) | 25 in. |
Model | Multisizer™ 4e |
Weight (English) | 170 lb. |
For Use With (Application) | Particle Counting and Detection |
Width (Metric) | 63.5 cm |
Power Supply | 100/210 VAC |
Weight (Metric) | 77 kg |
Height (English) | 20 in. |
Beckman Coulter LS 13 320 XR Particle Size Analyzer Sonicator Kit
An optional accessory for the LS 13 320 XR Universal Liquids Module (ULM). Sonication is a method to break up particle aggregates in order to facilitate sample preparation in a module.
Beckman Coulter LS 13 320 XR Multiwavelength (MW) Laser Diffraction Particle Size Analyzer Optical Bench
The LS 13 320 XR Laser Diffraction Particle Size Analyzer Multi-Wavelength (MW) Optical Bench features low-angle, forward light scattering with additional PIDS Technology. Optical Bench offers a measurement range of 0.010 μm to 3,500 μm and requires a Sampling Module, either ULM or DPS.
Beckman Coulter NIST Traceable Particle Size Standards
For calibrating Coulter Counter Aperture Tubes, and verifying their performance.
Product Type | Particle Size Standard |
---|---|
For Use With (Application) | Calibration and Performance Verification |
Beckman Coulter NIST Traceable Particle Size Standards
Recommended for LS Series Instruments to verify instrument and module performance.
For Use With (Application) | Verifying Instrument and Module Performance |
---|
Beckman Coulter Dry Powder System (DPS) for LS 13 320 XR Particle Size Analyzer
A sampling module for the LS 13 320 XR Particle Size Analyzer. The DPS is capable of feeding and measuring dry powder samples in the size range 0.40 μm to 3500 μm. The sample is placed in a DPS tube and delivered to the sensing zone in the optical bench by a required vacuum.
Beckman Coulter NIST Traceable Particle Size Controls
Particle Size Controls for use with LS 13 320 XR Analyzers to verify instrument and module performance.
For Use With (Equipment) | LS 13 320 XR Analyzer |
---|---|
Product Type | Particle Size Control |
For Use With (Application) | Verifying Instrument and Module Perfomance |
Beckman Coulter Accuvette™ ST Sampling Vials with Caps, 25 mL
Designed for use on the stage of the Multisizer 4e to ensure optimal fluid use and circulation with the locked platform height.
Beckman Coulter LS 13 320 XR Single Wavelength (SW) Laser Diffraction Particle Size Analyzer Optical Bench
The LS 13 320 XR Laser Diffraction Particle Size Analyzer Single Wavelength (SW) Optical Bench features low-angle, forward light scattering optics. Optical Bench requires a sampling module and offers a measurement range of 0.40 μm to 2,000 μm or 3,500 μm, depending on the selected module.
Beckman Coulter Universal Liquids Module (ULM) for LS 13 320 XR Particle Size Analyzer
The Universal Liquids Module (ULM) is a sampling module for use with the LS 13 320 XR Particle Size Analyzer. It measures the entire sample introduced to the instrument by re-circulating the sample, and requires relatively small volumes of sample and dispersing liquid (125 mL).
Beckman Coulter Multisizer™ 4e Smart Technology (ST) Footed Beakers
Smart Technology Beakers fit the built-in beaker guide for proper positioning allowing the Multisizer 4e to deliver consistent, optimal results.
For Use With (Equipment) | Multisizer 4e Coulter Counter with Smart Technology (ST) |
---|---|
Product Type | Footed Beaker |
Material | Glass |