
Calorimetry
Résultats de la recherche filtrée

Mettler Toledo™ DSC 5+ Differential Scanning Calorimeter
Differential scanning calorimetry (DSC) measures enthalpy changes in a material due to changes in physical and chemical properties as a function of temperature or time. The DSC 5+ sets the new standard, delivering a superior performing and more productive DSC.
Hauteur (impériale) | 36 in. |
---|---|
Précision | ± 0.2 K |
Type de produit | Differential Scanning Calorimeter |
Profondeur (impériale) | 22 in. |
Plage de températures (métrique) | -150°C to 700°C |
Largeur (impériale) | 22 in. |
À utiliser avec (application) | Melting Behavior, Crystallization and Nucleation, ad Polymorphism, Phase Diagrams and Composition, Glass Transitions, Curing, Stability, Effects of Plasticizers, Reaction and Transition Enthalpies, Heat Capacity and Heat Capacity Changes |
Eisco™ Steel Calorimeter Inner Vessel
Inner vessel for use with colorimeter experiments and demonstrations.
Parr™ 1341 Plain Jacket Calorimeter
For measuring heat of combustion of solid or liquid fuels, waste materials, and other combustible samples
Hertz | 50/60 Hz |
---|
METTLER TOLEDO™ High Temp Differential Scanning Calorimeter (DSC)
Measure samples with the most sensitive Differential Scanning Calorimeter on the market – ideal for investigating all kinds of materials and effects. Our revolutionary star-shaped arrangement of thermocouples guarantees flat baselines and reproducible measurement results.
Certifications/Conformité | IEC/EN61010-1:2001 |
---|---|
Précision | ±0.02K |
Profondeur (impériale) | 24.8 in. |
Tension | 115 V |
Largeur (impériale) | 18.1 in. |
Hertz | 50/60 Hz |
Parr™ Gelatin Capsule For Calorimeter
Weighs and Handles Volatile Liquid Samples to be Burned in Oxygen Bomb
Parr™ 6200 Isoperibol Calorimeter
For measuring heats of combustion of solid or liquid fuels, waste materials, and other combustible samples
Hauteur (impériale) | 17 in. |
---|---|
Certifications/Conformité | ISO 9001:2008, CSA, CE, ASTM |
Précision | 0.05 to 0.1% |
À utiliser avec (équipement) | Parr™ 1108 Bombs and Closed-circuit Water Handling Systems |
Types de connecteurs | Ethernet or USB |
Résolution de la température | 0.0001°C |
Type de produit | Isoperibol Calorimeter |
Gamme d’échantillons | 52 to 12,000 calories |
À utiliser avec (application) | Measuring heats of combustion of solid or liquid fuels, waste materials and other combustible samples |
Type d’affichage | LCD |
Durée de fonctionnement | 6 min./Test |
Heure du test | 4 to 7 Tests/hr. |
Largeur (métrique) | 57 cm |
Mémoire | Stores 1000 tests |
Hauteur (métrique) | 43 cm |
Profondeur (impériale) | 16 in. |
Largeur (impériale) | 23 in. |
Fonctionnement | Manual |
Profondeur (métrique) | 40 cm |
Hauteur (impériale) | 13 in. |
---|---|
Certifications/Conformité | ISO 9001:2008, CSA, CE, ASTM |
Précision | 0.004 |
Types de connecteurs | Ethernet or USB |
Résolution de la température | 0.0001°C |
Type de produit | Semi-micro Calorimeter |
Gamme d’échantillons | 52 to 1200 calories |
À utiliser avec (application) | Measuring the heat of combustion of small samples when only limited amounts of test material are available, ideal for use in marine biology, it can also be used for testing a variety of heat powders and pyrotechnic mixtures |
Durée de fonctionnement | 6 to 10 min./Test |
Heure du test | 2 to 3 Tests/hr. |
Largeur (métrique) | 22 cm |
Mémoire | Stores 1000 tests |
Hauteur (métrique) | 33 cm |
Profondeur (impériale) | 13 in. |
Comprend | 6772 precision calorimeter thermometer/controller, compensated jacket and dewar flask bucket, 1109A 22mL manual valve semi-micro bomb, SD memory and TCP/IP network communications, oxygen and bucket fill |
Largeur (impériale) | 9 in. |
Fonctionnement | Manual |
Profondeur (métrique) | 33 cm |
Parr™ 6400 Automatic Isoperibol Calorimeter
High throughput, with minimum operator time between tests
Hauteur (impériale) | 20 in. |
---|---|
Certifications/Conformité | ISO 9001:2008, CSA, CE, ASTM |
Précision | 0.001 |
Types de connecteurs | Ethernet or USB |
Résolution de la température | 0.0001°C |
Type de produit | Automatic Isoperibol Calorimeter |
Gamme d’échantillons | 5000 to 8000 calories |
À utiliser avec (application) | Measuring heats of combustion of solid or liquid fuels, waste materials and other combustible samples |
Durée de fonctionnement | 1 min./Test |
Heure du test | 6 to 7 Tests/hr. |
Largeur (métrique) | 42 cm |
Mémoire | Stores 1000 tests |
Hauteur (métrique) | 51 cm |
Profondeur (impériale) | 15.5 in. |
Largeur (impériale) | 16.5 in. |
Fonctionnement | Automatic |
Profondeur (métrique) | 40 cm |
Parr™ 6765 Combined Solution and Semi-Micro Calorimeter
Performs both solution and semi-micro oxygen bomb calorimetry tests
Hauteur (impériale) | 13 in. |
---|---|
Certifications/Conformité | ISO 9001:2008, CSA, CE, ASTM |
Précision | 0.004 |
Types de connecteurs | Ethernet or USB |
Type de produit | Combined Solution and Semi-micro Calorimeter |
Gamme d’échantillons | 2 to 1000 calories |
À utiliser avec (application) | Used to perform both solution and semi-micro oxygen bomb calorimetry tests |
Type d’affichage | LCD |
Largeur (métrique) | 22 cm |
Hauteur (métrique) | 33 cm |
Profondeur (impériale) | 13 in. |
Plage de températures (métrique) | 10°C to 50°C |
Comprend | 6772 calorimetric thermometer, calorimeter module and conversion parts for both the 6755 solution calorimeter and the 6725 semi-micro calorimeter |
Largeur (impériale) | 9 in. |
Plage de températures (impériale) | 50°F to 122°F |
Profondeur (métrique) | 33 cm |
Parr™ 6420 Expanded System Featuring the 6400 Automatic Isoperibol Calorimeter
Compact complete system
IKA™ C 6000 Calorimeter Global Standards Package 1/12
The C 6000 global standards oxygen bomb calorimeter combines modern technology, variability and automation in one instrument. It operates according to all bomb calorimeter standards, such as DIN, ISO, ASTM, GOST and GB.