missing translation for 'onlineSavingsMsg'
Learn More

Mettler Toledo™ DSC 5+ Differential Scanning Calorimeter

Differential scanning calorimetry (DSC) measures enthalpy changes in a material due to changes in physical and chemical properties as a function of temperature or time. The DSC 5+ sets the new standard, delivering a superior performing and more productive DSC.

Specifications

Product Type Differential Scanning Calorimeter
Depth (English) 22 in.
For Use With (Application) Melting Behavior, Crystallization and Nucleation, ad Polymorphism, Phase Diagrams and Composition, Glass Transitions, Curing, Stability, Effects of Plasticizers, Reaction and Transition Enthalpies, Heat Capacity and Heat Capacity Changes
Height (English) 36 in.
Precision ± 0.2 K
View More Specs

Products 2
Catalog Number Mfr. No. Operation Price Quantity  
Catalog Number Mfr. No. Operation Price Quantity  
01-338-205
View Documents
Mettler Toledo™
30877113
Manual N/A
N/A
Please call Customer Service at 1-800-234-7437 or send an email to help@thermofisher.com for assistance.
01-338-204
View Documents
Mettler Toledo™
30877114
Automatic N/A
N/A
Please call Customer Service at 1-800-234-7437 or send an email to help@thermofisher.com for assistance.
Description

Description

  • FlexMode™: choose power compensation or heat flux mode
  • Power compensation: provides outstanding resolution for separating close-lying effects
  • MultiSTAR™ sensor with 136 thermocouples: exceptional sensitivity for the measurement of weak effects
  • Patented electrical heat flow adjustment: saves time and ensures excellent measurement accuracy
  • Time-saving FlexCal™ adjustment: guarantees accurate results under all measurement conditions
  • Innovative robot with gas-purged sample chamber: protects samples from the environment and operates reliably around the clock
  • Unrivalled modular concept: tailor-made solutions for current and future needs
  • Huber cooling system required for use with the DSC 5+ (item #30857474 or 30857475)

Note: This is a configurable instrument; additional METTLER TOLEDO accessories and software are required. Please contact your local Fisher Scientific Sales Representative to discuss the best configuration for your application.

Specifications

Specifications

Differential Scanning Calorimeter
Melting Behavior, Crystallization and Nucleation, ad Polymorphism, Phase Diagrams and Composition, Glass Transitions, Curing, Stability, Effects of Plasticizers, Reaction and Transition Enthalpies, Heat Capacity and Heat Capacity Changes
± 0.2 K
22 in.
22 in.
36 in.
-150°C to 700°C
Videos
SDS
missing translation for 'documents'

missing translation for 'documents'