Chromatography Media

Chromatography Media
- (2)
- (7)
- (2)
- (2)
- (1)
- (2)
- (22)
- (4)
- (2)
- (1)
- (2)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (4)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (4)
- (1)
- (2)
- (4)
Résultats de la recherche filtrée

Thermo Scientific™ OLIGO™ R3 Column, 4.6 x 100 mm, 1.7 mL
Thermo Scientific™ Oligo™ R3 bulk resin is a rigid polymeric bead designed for reversed-phase chromatography of polynucleotides and other biomolecules.
Thermo Scientific™ OLIGO™ R3 Column, Stainless Steel, 4.6 x 100 mm, 1.7 mL
Thermo Scientific™ Oligo™ R3 bulk resin is a rigid polymeric bead designed for reversed-phase chromatography of polynucleotides and other biomolecules.
Thermo Scientific™ POROS™ XS Strong Cation Exchange Resin
Thermo Scientific™ POROS™ XS resin is the first high-capacity, high-resolution resin that allows loading to more than 100 mg/mL capacity in the presence of up to 15 mS/cm NaCl, while delivering unprecedented separation capability.
Gamme de produits | POROS |
---|---|
Granulométrie | 50 μm |
Phase stationnaire | XS Ion Exchange Phase |
Conditions d’expédition | Room Temperature |
Contenu et stockage | Store at room temperature. |
Cytiva Strep-Tactin™ XT Sepharose™ Chromatography Resin
Chromatography resin for purification of recombinant proteins tagged with a Strep-tag™ II and Twin-Strep-tag™.
Plage de pH | 6 to 10 pH |
---|---|
Densité (métrique) | Approx. 5 mg/mL resin |
Capacité de liaison | Approx. 10 mg protein with Strep-tag II or Twin-Strep-tag/mL of resin |
Conditions de stockage | 2 to 8°C in 20% ethanol |
Stabilité | Stable in all commonly used aqueous buffers |
Type de ligand | Strep-Tactin XT |
Matrice | Rigid, cross-linked agarose, spherical |
Granulométrie | 34 μm |
À utiliser avec (application) | Purification of recombinant proteins tagged with Strep-tag II and Twin-Strep-tag |
Cytiva HiScreen™ Capto™ PlasmidSelect
For purification of supercoiled DNA to high quality, for gene therapy and DNA vaccine applications
Cytiva HiTrap™ Capto™ PlasmidSelect
For the purification of supercoiled DNA to high quality for gene therapy and DNA vaccine applications
Longueur (métrique) | 2.5 cm |
---|---|
Matrice | Capto™ PlasmidSelect |
Type de produit | Chromatography Resin |
Pression max. | 5 bar (0.5 MPa) |
À utiliser avec (application) | Purification of Supercoiled DNA From Research Scale to cGMP Production |
Cytiva HiTrap™ AVB Sepharose™ Columns
Enables purification of adeno associated viruses (AAV) in one step, with high purity and excellent yields. Cytiva HiTrap™ AVB Sepharose™ Columns are pre-packed with affinity chromatography medium (resin) for simple operation with a syringe, pump or chromatographic system.
Plage de pH | 3 to 10 |
---|---|
Débit | <150 cm/hr |
Capacité de liaison | >10▿12 genecopies/mL Chromatography Mediμm |
Conditions de stockage | Store prepacked column at 4°C to 30°C in 20% Ethanol and Media at 4°C to 8°C in 20% Ethanol. |
Stabilité | Stable to all commonly used aqueous buffers |
Type de ligand | 14 kD recombinant protein |
Matrice | Cross-linked agarose |
Matériau | Polypropylene |
Type de produit | HiTrap AVB Sepharose HP Column |
Hauteur (métrique) du lit | 25 mm |
Granulométrie | 24 to 44 μm |
Pression max. | 70 psi (5 bar) |
À utiliser avec (application) | One Step Purification of Adeno Associated Viruses |
Cytiva Q Sepharose™ XL
Hydrophilic base matrix ensures low levels of non-specific binding leading to low levels of host cell-derived impurities in elution pool
Cytiva HiTrap™ TALON™ Crude Prepacked Columns
For purification of histidine-tagged recombinant proteins by immobilized metal affinity chromatography (IMAC). Cytiva Lifescience™ HiTrap™ TALON™ Crude Prepacked Columns offer a cobalt-based medium allowing protein purification under native or denaturing conditions.
Tampon de stockage | 20% Ethanol |
---|---|
Plage de pH | 3 to 12 |
Débit | 1 to 4 mL/min |
Conditions de stockage | 4°C to 8°C |
Type de ligand | Talon Superflow Cobalt-IMAC |
Matrice | 6% Cross-Linked Agarose |
Matériau | Polypropylene |
Type de produit | HiTrap Talon crude prepacked Column |
Granulométrie | 60 to 160 μm |
Pression max. | 3 bar |
À utiliser avec (application) | For PurifiCatIon of Histidine-Tagged Recombinant Proteins by Immobilized Metal Affinity Chromatography, Used Buffers and Easily Regenerated with 0.5 M NaOH |
Cytiva His MultiTrap™ TALON™
For high-throughput screening of histidine-tagged proteins from clarified cell lysates
Cytiva His SpinTrap™ TALON™
Single-use spin column for high purity purification of histidine-tagged proteins
Cytiva Sephaorose™ Fast Flow Anion Exchange Media: ANX
Used for preparative protein separations in both research and industrial applications
Plage de pH | 3 to 13 pH |
---|---|
Type de produit | ANX Sepharose 4 Fast Flow |
À utiliser avec (application) | For Protein Separations in Research/Industrial Applications |
Cytiva Blue Sepharose™ 6 Fast Flow Chromatography Media
Blue dye binds to proteins such as albumin and lipoproteins as well as enzymes like kinases and dehydrogenases
Cytiva rProtein A Sepharose™ Fast Flow Affinity Media
Designed for purification of monoclonal and polyclonal antibodies at labs and process scales
Tampon de stockage | 20% Ethanol |
---|---|
Plage de pH | 2 to 9 |
Débit | 150 to 250 cm/Hoμr |
Conditions de stockage | 2°C to 8°C |
Stabilité | Stable in aqueous Buffers commonly used in Protein A Chromatography |
Type de ligand | Recombinant Protein A (E. coli) |
Matrice | 4% Cross-Linked Agarose |
Type de produit | rProtein A Sepharose Fast Flow Media |
Hauteur (métrique) du lit | 25 cm |
Granulométrie | 60 to 165 μm |
Pression max. | 100 kPa |
Hauteur (impériale) du lit | 9.84 in. |
À utiliser avec (application) | For PurifiCatIon of Monoclonal and Polyclonal Antibodies at Labs and Process Scales |