Invitrogen™ Neon™ NxT Electroporation System Starter Pack
The Neon NxT Electroporation System Starter Kit with 1-Channel Pipette contains a Neon NxT Electroporation System with 1-channel pipette and pipette station as well as 192-reaction kits (10-μLL and 100-μLL sample sizes) to get you started in a convenient and cost-effective manner.
Product Type | Neon™ NxT Electroporation System Starter Pack |
---|---|
Voltage | 100/240 VAC |
Wattage | 270 W |
Quantity | Each |
For Use With (Application) | Transfection |
Interface | Touchscreen |
Display | Color Touchscreen |
Invitrogen™ Neon™ NxT Electroporation System
The Neon NxT Electroporation System is a next-generation electroporation platform leveraging the unique and trusted Neon electroporation technology, which increases transfection efficiency and cell viability.
Invitrogen™ Neon™ NxT Electroporation System
The Neon NxT Electroporation System with 1-Channel Pipette is a next-generation electroporation platform leveraging the unique and trusted Neon electroporation technology, which increases transfection efficiency and cell viability.
Voltage Range (LV Mode) | 500 to 2500 V (Electroporation) |
---|---|
Content And Storage | • Neon NxT electroporation device • 1-Channel Pipette • 1-Channel Pipette Station • Power cord • Quick reference guide |
Electrical Requirements | 100/240 VAC, 50/60 Hz, 270 VA |
Wattage | 270 W |
Quantity | Each |
For Use With (Application) | Transfection |
Pulse Number Range | 1 to 10 Pulses |
Format | Flasks, Plates (6-well, 12-well, 24-well, and 96-well) |
Pulse Width Range | 1 to 100 ms |
Product Type | Neon™ NxT Electroporation System |
Voltage | 100/240 VAC |
Voltage Range (HV Mode) | 500 to 2500 V (Electroporation) |
Interface | Touchscreen |
Display | Color Touchscreen |
Invitrogen™ Electroporation Cuvettes, 0.2 cm
Electroporation uses short, high-voltage electric pulses to overcome the cell membrane and introduce DNA directly into cells. These cuvettes are specifically designed help achieve high DNA transformation efficiency during the introduction of DNA into bacterial, yeast, fungal, and mammalian cells.
Invitrogen™ Electroporation Cuvettes, 0.1 cm
Electroporation uses short, high-voltage electric pulses to overcome the cell membrane and introduce DNA directly into cells. These cuvettes are specifically designed help achieve high DNA transformation efficiency during the introduction of DNA into bacterial, yeast, fungal, and mammalian cells.
BTX™ Two-Needle Array™ Electrodes
Two-Needle Array™ Electrodes designed for in vivo drug or gene delivery.
Length (Metric) Electrode | 20 mm |
---|---|
Length (English) Electrode | 0.78 in. |
For Use With (Equipment) | ECM 830, ECM 2001+, ECM 630, Legacy ECM 2001 Generator |
Connection Type | Banana Plug to Banana Plug |
Voltage | 500 V |
Pulse Form | Square Wave |
Quantity | 6 Pk. |
Pulse Length Range | 10 μsec. to 99 msec. in PBS |
For Use With (Application) | In-Vivo Drug or Gene Delivery, Muscle Gene Therapy |
Sterility | Sterile |
Electrode Shape | Straight/Needle |
BTX™ ECM™ 630 Generator Only
ECM™ 630 Generator for the ECM™ 630 Exponential Decay Wave Electroporator is ideal for efficient transformation of bacteria, yeast and other microorganisms.
BTX™ Two-Needle Array™ Electrodes: Handle Only
Handle for use with BTX Two-Needle Array™ Electrodes (cat. no. BTX531).
Product Type | Electroporation accessory |
---|---|
Connection Type | Banana Cables |
Voltage | 500 V |
Pulse Form | Square Wave |
Quantity | 1 Ea. |
Pulse Length Range | 10 μsec. to 99 msec. in PBS |
Material | Delrin |
For Use With (Application) | In-Vivo Drug or Gene Delivery, Muscle Gene Therapy |
Sterility | Non-sterile |
Product Line | BTX Electroporation |
BTX™ Tweezertrode™ Electrode Kit
Tweezertrode™ Electrode Kit features reusable, tweezer-style, in vivo electrodes suitable for drug or gene delivery in animals.
Length (Metric) Electrode | 12 mm |
---|---|
Length (English) Electrode | 0.47 in. |
Relative Humidity | 20 to 80% |
Pulse Form | Square Wave |
Quantity | 1 Ea. |
Pulse Length Range | 10 μsec. to 99 msec. in PBS |
Material | Stainless Steel |
For Use With (Application) | In vivo applications, including in utero and ex-vivo gene transfection, eletroporation therapy, and transdermal drug delivery. |
Sterility | Non-sterile |
Electrode Shape | Circular |
Includes | Cable |
Size (Metric) Gap | <1 mm to >2 cm |
Product Type | Electrode Kit |
Connection Type | Banana Cables |
Tweezer Size | 11.5 cm |
Voltage | 1000 V |
Size (English) Gap | <0.04 in. to >0.79 in. |
Product Line | BTX Electroporation |
BTX™ Two-Needle Array™ Electrode Kit
Two-Needle Array™ Electrode Kit designed for in vivo drug or gene delivery.
Length (Metric) Electrode | 20 mm |
---|---|
Length (English) Electrode | 0.78 in. |
Connection Type | Banana Cables |
Voltage | 500 V |
Pulse Form | Square Wave |
Operating Temperature (Metric) | 5°C to 40°C |
Pulse Length Range | 10 μsec. to 99 msec. in PBS |
Material | Stainless Steel, Delrin |
For Use With (Application) | In-Vivo Drug or Gene Delivery, Muscle Gene Therapy |
Sterility | Non-sterile |
Product Line | BTX Electroporation |
BTX™ Gemini X2 Electroporation Generator Footswitch
Allows for hands free operation of Gemini X2, ECM2001+, ECM830 and ECM630 generator (touch screen models). Harvard Apparatus Gemini X2 Electroporation Footswitch functions as the start button on front of the generator.
BTX™ ECM™ 399 Exponential Decay Wave Electroporator
ECM™ 399 Exponential Decay Wave Electroporator is a portable, user-friendly system designed to produce the precise field strengths and pulse lengths required for the transformation of bacterial and yeast cells and limited transfection of mammalian cells.
Mirus Bio™ Ingenio™ EZporator™ Electroporation System
Mirus Bio™ Ingenio™ EZporator™ Electroporation System provides a robust and universal approach for multiple insect and mammalian cell culture applications, including gene expression, RNAi, stable cell line generation, and CRISPR/Cas genome editing.
BTX™ Gemini SC Electroporation System Complete, for Cuvettes
Gemini SC Twin Wave Electroporators offer flexibility for electroporation of all cell types
BTX™ ECM™ 830 Square Post Adapters to Banana Plug Cables (45-0217)
ECM™ 830 Square Post Adapters to Banana Plug Cables (45-0217) for use with ECM™ 830.