Filtration Membrane Discs

Filtration Membrane Discs
Thin, precut membrane rounds for high-throughput, fast filtration of liquid and gas samples. Gridded and non-gridded discs. Various materials including mixed cellulose ester, polycarbonate, PTFE, nylon, and PVDF. For air monitoring/analytical research.
Sizes
Filter membranes are made in a range of diameters, typically designed to fit a specific holder or manifold.
Materials
Filter membrane can be made from cellulose, mixed cellulose esters (MCE), polyvinylidene fluoride (PVDF), polyethersulfone (PES), polyvinyl chloride (PVC), polytetrafluoroethylene (PTFE), nylon, polycarbonate (PC), polyester, polyethylene terephthalate (PET), and polypropylene (PP). Other membrane materials include aluminum oxide, gelatin, porcelain, and glass.
Pore Size
The size of membrane pores determines which particles will be retained by the filter. A pore size of 0.2 µm is small enough to remove microbes from solutions; a 0.45 µm ore size can remove larger particulates.
Color and Grids
White membrane filters may be plain or marked with square grids (outlined in black) that can help with enumerating particles. Gridded or plain black membrane filters may be helpful when filtering light-colored particulates.
Sterility
Filter membranes may be pre-sterilized or may be sterilized using ethylene oxide, gamma irradiation, or autoclaves. The need for sterility is determined by the application, which are many and varied:
- Light microscopy samples
- Cytology sample preparation
- Electron microscopy samples
- Air quality and other environmental monitoring
- Water analysis and water quality testing
- Microbiology colony counting and quality control
- Chemotaxis
- Sterile preparation of buffers, tissue culture media, microbiological media, and other biological fluids
- (1)
- (4)
- (5)
- (1)
- (4)
- (31)
- (124)
- (46)
- (3)
- (24)
- (191)
- (41)
- (10)
- (22)
- (6)
- (87)
- (7)
- (19)
- (51)
- (17)
- (6)
- (4)
- (2)
- (2)
- (15)
- (23)
- (60)
- (5)
- (23)
- (11)
- (1)
- (74)
- (8)
- (160)
- (3)
- (3)
- (1)
- (177)
- (1)
- (3)
- (5)
- (52)
- (26)
- (20)
- (94)
- (1)
- (1)
- (45)
- (14)
- (90)
- (4)
- (1)
- (22)
- (1)
- (1)
- (488)
- (115)
- (1)
- (3)
- (1)
- (2)
- (1)
- (324)
- (1)
- (5)
- (3)
- (160)
- (71)
- (241)
Filtered Search Results

MilliporeSigma™ MF-Millipore™ Membrane Filter, 0.45 μm
MF-Millipore™ Membrane Filter are mixed cellulose esters (MCE) membrane, hydrophilic.
Thickness (Metric) | 150 μm |
---|---|
Pore Size | 0.45 μm |
Disposable | Reusable |
Flow Rate | 60 mL/min. x cm2 |
Wettability | Hydrophilic |
Type | Filter Membranes |
Material | MCE |
Filter Type | Membrane Filter |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |
Thickness (Metric) | 125 μm |
---|---|
Pore Size | 0.45 μm |
Bubble Point | 22 psi |
Flow Rate | >2.6 mL/min x cm2 |
Wettability | Hydrophilic |
Type | Filter Membranes |
Color | White |
Material | PVDF |
Filter Type | Screen Filter |
Hydrophobicity | Hydrophilic |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |
Sartorius PTFE (Polytetrafluorethylene) Membrane Filters
Filter air and gasses, even at low differential pressures. Sartorius PTFE (Polytetrafluorethylene) Membrane Filters are permanently hydrophobic with low adsorption and excellent chemical compatibility. Choose from four pore sizes in a variety of diameters.
Disposable | Single-use |
---|---|
Type | Membrane Filter |
Material (Membrane) | PTFE |
Color | White |
Material | PTFE |
Filter Type | Membrane Filter |
Hydrophobicity | Hydrophobic |
For Use With (Application) | Air/gas-filtration |
Autoclavable | Autoclavable |
Cytiva Whatman™ Anodisc™ Filter Membranes
Constructed with precision pore structure and narrow pore size distribution. Whatman™ Anodisc™ Filter Membranes ensure a high level of particle removal efficiency. Captures microorganisms and particulates on the surface of the membrane for subsequent analysis.
Material | Aluminum Oxide |
---|
Material | MCE |
---|---|
For Use With (Application) | For all analytical, ultracleaning, and sterilizing applications at temperatures below 75°C (167°F) – except those involving esters, ether-alcohols, ketones, nitroparaffins or strong acids and bases. |
Autoclavable | Autoclavable |
Cytiva Whatman™ Type WCN Cellulose Nitrate Membranes
Recommended for majority of routine applications, this membrane is manufactured under strictly controlled conditions. Whatman™ Type WCN Cellulose Nitrate Membranes narrow pore size distribution for improved surface capture and analysis.
Color | White |
---|---|
Material | Cellulose Nitrate |
Autoclavable | Autoclavable |
MilliporeSigma™ Express™ PLUS Membrane Filters
Plain white polyethersulfone Express™ PLUS Membrane Filters provide ultrafast filtration for a variety of applications.
Disposable | Reusable |
---|---|
Wettability | Hydrophilic |
Type | Filter Membranes |
Format | Disc |
Color | White |
Material | PES |
Filter Type | Screen Filter |
Hydrophobicity | Hydrophilic |
For Use With (Application) | Provide ultrafast filtration of tissue culture media, additives, buffers and other aqueous solutions. This membrane is also used in many ready-to-use sterile filtration devices. |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |
MilliporeSigma™ MF-Millipore™ Mixed Cellulose Ester Membranes, Triton-free
MF-Millipore™ Mixed Cellulose Ester Membranes, Triton-free composed of mixed cellulose esters (nitrate and acetate).
Disposable | Reusable |
---|---|
Wettability | Hydrophilic |
Format | Disc |
Color | White |
Material | MCE |
Filter Type | Membrane Filter |
For Use With (Application) | Clarification of fluids, Sterilizing filtration of tissue culture media, additives, antibiotics, Air monitoring, Particulate analysis, Particulate removal, Biological assays (receptor binding studies, TCA precipitates, etc.). |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |
Membrane Type | Plain |
Sartorius Cellulose Nitrate Membrane Filters
Combines uniform pore structure with high flow and adsorption rates. Sartorius Cellulose Nitrate Membrane Filters are excellently suited for diagnostic kits. Non-sterile, hydrophilic filters in a variety of diameters and pore sizes are bulk-packed to save money and space.
Thickness (Metric) | 130 μm |
---|---|
Disposable | Single-use |
Type | Membrane Filter |
Format | Disc |
Material (Membrane) | Cellulose Nitrate |
Color | White |
Material | Cellulose Nitrate |
Filter Type | Membrane Filter |
Hydrophobicity | Hydrophilic |
Autoclavable | Autoclavable |
Sterility | Non-sterile |
Sartorius Hydrophobic Edged Nonsterile Cellulose Nitrate and Acetate Membrane Filters
The non-sterile membrane filters are made of cellulose nitrate (cellulose mixed ester), cellulose acetate or regenerated cellulose. They can be used for colony counting, particle testing and microscopy. Choose between gridded or non-gridded, membranes, either with or without hydrophobic edge.
Disposable | Single-use |
---|---|
Type | Membrane Filter |
Format | Disc |
Color | White |
Filter Type | Membrane Filter |
Hydrophobicity | Hydrophobic |
Sterility | Non-sterile |
Sartorius Nongridded Sterile Cellulose Membrane Filters
Ensure quality control in routine microbiological filtering. Sartorius Nongridded Sterile Cellulose Membrane Filters are single-packed membranes used for colony counting, particle testing, microscopy and sterility testing. Choose between cellulose acetate or cellulose nitrate membranes in a variety of pore sizes.
Disposable | Single-use |
---|---|
Type | Membrane Filter |
Format | Disc |
Color | White |
Individually wrapped | Yes |
Filter Type | Membrane Filter |
No. per Pack | 100/Pk. |
Hydrophobicity | Hydrophilic |
For Use With (Application) | For colony count; sterility testing; particle count; microscopy |
Sterility | Sterile |
Sartorius Polyamide (Nylon) Membrane Filters
Recommended for particle-removing filtration of water, aqueous solutions and solvents for analytical determination. Sartorius Polyamide (Nylon) Membrane Filters are white, non-sterile filters without grids. Choose from two pore sizes in four diameters. Bulk packed for space and cost savings.
Thickness (Metric) | 115 μm |
---|---|
Disposable | Single-use |
Type | Membrane Filter |
Format | Disc |
Color | White |
Material | Polyamide |
Filter Type | Membrane Filter |
Hydrophobicity | Hydrophilic |
For Use With (Application) | Recommended for particle removing filtration of water; aqueous solutions and solvents for analytical determination. |
Autoclavable | Autoclavable |
Sterility | Non-sterile |
Cytiva Whatman™ Mixed Cellulose Ester Membrane Filters
Whatman™ Mixed Cellulose Ester Membrane Filters are biologically inert and offers high degree of internal surface area for greater product adsorption.
Material | MCE |
---|---|
Autoclavable | Autoclavable |
Sterility | Sterile |
Cytiva Whatman™ Nuclepore™ Hydrophilic Membrane
A highly defined pore size cutoff in the sub-micron range enables particle deformity measurements, and the capture of extremely small particles
Type | Track Etched Hydrophilic Membrane Filters |
---|---|
Shape | Circle |
Hydrophobicity | Hydrophilic |
For Use With (Application) | Bioassays, Cell Biology and Environment Analysis |
Membrane Type | Polycarbonate Film Track-Etched (PFTE) |
Cytiva Whatman™ 19mm Nuclepore™ Polycarbonate Track-Etched Membranes
Manufactured from high-quality polycarbonate film and track-etched for high pore size precision. Whatman™ 19mm Nuclepore™ Polycarbonate Hydrophilic Membranes combine high flow rates and chemical and thermal resistance with sharply defined pores, making them suitable for microscopy, cytology, parasitology, and certain air and oceanography analyses.
Flow Rate | High |
---|---|
Diameter (Metric) | 19 mm |
Material | Polycarbonate |
Hydrophobicity | Hydrophilic |