HPLC Columns and Cartridges

HPLC Columns and Cartridges
Filtered Search Results

Thermo Scientific™ HyPURITY™ C18 HPLC Columns, 3μm Particle Size
Thermo ScientificTM HyPURITYTM C18 HPLC Columns are available in limited dimensions. Please contact Customer Service for more details.
Thermo Scientific™ HyPURITY™ C18 Columns, 5μm Particle Size
High quality, highly pure silica columns
Pore Size | 190 Å |
---|---|
Particle Size | 5 μm |
Carbon Load | 13% |
Stationary Phase | C18 |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Silica |
Column Type | Reversed Phase |
pH | 1 to 9 |
Surface Area | 200 m²/g |
USP Type | L1 |
Thermo Scientific™ Hypercarb™ Porous Graphitic Carbon HPLC Columns
Use for enhanced retention of polar compounds and separation of structurally related analytes with stability at pH extremes and high temperature.
Thermo Scientific™ Hypersil GOLD™ C18 Selectivity HPLC Columns
Use these endcapped, ultrapure, silica-based columns to generate exceptional peak shape and resolution for HPLC and LC/MS analyses using generic gradients
Thermo Scientific™ Acclaim™ C30 HPLC Columns
Use for superior separation of hydrophobic structural isomers.
Pore Size | 200 Å |
---|---|
Carbon Load | 13% |
Stationary Phase | C30 |
Temperature | 60°C |
Phase | Reversed Phase |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 200 m²/g |
Product Line | Acclaim |
Thermo Scientific™ BetaBasic™ Javelin™ C18 Reversed Phase HPLC Column, 5 μm, 4 mm x 20 mm
Column Format: Guard Column; Carbon Load: 13%; Pore Size: 150 Å; Column Phase: Reversed Phase
Thermo Scientific™ μPAC™ HPLC Columns
Learn more about your proteome, metabolome, and lipidome samples with Thermo Scientific™ μPAC™ HPLC columns.
Pore Size | 100 to 200 Å |
---|---|
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Silicon Chip |
Column Type | Micro Pillar Array |
pH | 1.5 to 7 |
Interpillar Distance | 2.5 μm |
Porosity | 59% |
Pillar Diameter | 5 μm |
Max. Pressure | 350 bar (5076 psi) |
Thermo Scientific™ Hypersil GOLD™ VANQUISH™ C18 UHPLC Columns
Obtain exceptional peak shape and high resolution for fast UHPLC high-pressure, high-throughput applications using generic gradients on Vanquish UHPLC and LC/MS systems.
Pore Size | 175 Å |
---|---|
Stationary Phase | C18 Selectivity |
Temperature | 60°C |
Phase | Reversed Phase |
For Use With | LC/MS |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 220 m²/g |
Column Format | Analytical Column |
Particle Size | 1.9 μm |
Carbon Load | 11% |
Packing Material | Spherical, Fully Porous, Ultrapure Silica |
Diameter (Metric) | 2.1 mm |
pH | 1 to 11 |
Technique | Bio-LC |
Product Line | Hypersil GOLD |
USP Type | L1 |
Thermo Scientific™ Hypersil GOLD™ VANQUISH™ aQ UHPLC Columns
Use for UHPLC high pressure applications to retain and resolve polar analytes with highly aqueous mobile phases on the Vanquish UHPLC system.
Pore Size | 175 Å |
---|---|
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
For Use With | HILIC |
Endcapped | Polar |
Column Type | Reversed Phase |
Surface Area | 220 m²/g |
Max. Pressure | 18130 psi (1250 bar) |
Column Format | Analytical Column |
Particle Size | 1.9 μm |
Carbon Load | 12% |
Packing Material | Spherical, Fully Porous, Ultrapure Silica |
Diameter (Metric) | 2.1 mm |
pH | 2 to 9 |
Product Line | Hypersil GOLD |
USP Type | L1 |
Thermo Scientific™ Accucore™ Polar Selectivity Kits
Verify optimum selectivity of Thermo Scientific™ Accucore™ HPLC columns for polar analytes.
Pore Size | 80 Å |
---|---|
Particle Size | 2.6 μm |
Stationary Phase | aQ C18, HILIC, PFP |
For Use With | HPLC |
Endcapped | Yes |
Packing Material | Silica |
Diameter (Metric) | 2.1 mm |
Surface Area | 130 m²/g |
Particle Shape | Spherical Solid Core |
Column Format | HPLC Column Kit |
Thermo Scientific™ Hypersil GOLD™ aQ Javelin™ Guard HPLC Columns
Javelin guard columns offer convenient, easy to use protection for analytical HPLC columns
Thermo Scientific™ Acclaim™ VANQUISH™ C18 UHPLC Columns
Use for high-pressure applications, such as the Vanquish UHPLC system's extended pressure capabilities, for greater power of separation, speed, and throughput.
Pore Size | 120 Å |
---|---|
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
For Use With | LC/MS |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 300 m²/g |
Max. Pressure | 21756 psi (1500 bar) |
Column Format | Analytical Column |
Particle Size | 2.2 μm |
Carbon Load | 18% |
Packing Material | Spherical, Fully Porous, Ultrapure Silica |
Diameter (Metric) | 2.1 mm |
pH | 2 to 8 |
Technique | Bio-LC |
Product Line | Acclaim |
USP Type | L1 |
Thermo Scientific™ Accucore™ Narrow Selectivity Kits
Verify optimum selectivity of Thermo Scientific™ Accucore™ HPLC columns over a narrow range.
Pore Size | 80 Å |
---|---|
Particle Size | 2.6 μm |
Stationary Phase | aQ C18, C18, RP-MS |
For Use With | HPLC |
Endcapped | Yes |
Diameter (Metric) | 2.1 mm |
Surface Area | 130 m²/g |
Particle Shape | Spherical Solid Core |
Column Format | HPLC Column Kit |
Thermo Scientific™ EASY-Spray™ PepMap™ Neo UHPLC Columns
Separate challenging peptide mapping samples with Thermo Scientific™ EASY-Spray™ PepMap™ Neo UHPLC columns.
Pore Size | 100 Å |
---|---|
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
For Use With (Application) | Bottom-up Proteomics, LC-MS |
Surface Area | 450 m2/g |
Max. Pressure | 22,000 psi (1500 bar) |
Column Format | Analytical Column, EASY-Spray™ |
Particle Size | 2 μm |
Carbon Load | 15% |
Packing Material | Spherical, Fully Porous, Ultrapure Silica |
Diameter (Metric) | 75 μm |
pH | 2 to 8 |
Product Line | Easy Spray |
USP Type | L1 |
Thermo Scientific™ PepMap™ Neo Trap Cartridge
Use the Thermo Scientific™ PepMap™ Neo Trap Cartridge with PepMap™ Neo UHPLC Columns to filter impurities from your peptide mapping samples.