HPLC Columns and Cartridges
Filtered Search Results

Thermo Scientific™ HyPURITY™ C18 HPLC Columns, 3μm Particle Size
Thermo ScientificTM HyPURITYTM C18 HPLC Columns are available in limited dimensions. Please contact Customer Service for more details.
Thermo Scientific™ Hypercarb™ Porous Graphitic Carbon HPLC Columns
Use for enhanced retention of polar compounds and separation of structurally related analytes with stability at pH extremes and high temperature.
Thermo Scientific™ HyPURITY™ C18 Columns, 5μm Particle Size
High quality, highly pure silica columns
Pore Size | 190 Å |
---|---|
Particle Size | 5 μm |
Carbon Load | 13% |
Stationary Phase | C18 |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Silica |
Column Type | Reversed Phase |
pH | 1 to 9 |
Surface Area | 200 m²/g |
USP Type | L1 |
Thermo Scientific™ Accucore™ Polar Premium HPLC Columns
Use this specially designed solid core column for fast high resolution with high pH stability for separation of basic, neutral, and acidic species.
Pore Size | 150 Å |
---|---|
Temperature | 70°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 90 m²/g |
Max. Pressure | 14500 psi (1000 bar) |
Particle Size | 2.6 μm |
Carbon Load | 9% |
Packing Material | Spherical, Solid Core, Ultrapure Silica |
pH | 1.5 to 10.5 |
Particle Shape | Spherical Solid-core |
Product Line | Accucore |
USP Type | L60 |
Thermo Scientific™ Hypercarb™ HPLC Column, 5μm
Thermo Scientific™ Hypercarb™ Columns give you 100% porous graphitic carbon for extended separation capabilities
Pore Size | 250 Å |
---|---|
Particle Size | 5 μm |
Carbon Load | 100% |
Phase | Normal and Reversed Phase |
Column Type | Mixed Mode |
pH | 1 to 14 |
Surface Area | 120 m²/g |
USP Type | L109 |
Column Format | Analytical Column |
Thermo Scientific™ Acclaim™ Trinity P2 HPLC Columns
Use these mixed-mode columns for separation of multivalent cations or anions and pharmaceuticals.
Pore Size | 300 Å |
---|---|
Solvents | Compatible with most common HPLC organic solvents except for alcohols |
Stationary Phase | Spherical, Nanopolymer Hybrid Silica |
Temperature | 45°C |
Phase | HILIC and Ion Exchange |
Endcapped | Proprietary |
Column Type | Mixed Mode |
Green Features | Responsibly packaged |
Surface Area | 100 m²/g |
Max. Pressure | 6000 psi (415 bar) |
Particle Size | 3 μm |
Mobile Phase Compatibility | 0 to 100% aqueous mobile phase |
pH | 2.5 to 7 |
Particle Shape | Spherical silica |
Product Line | Acclaim |
Thermo Scientific™ Hypersil™ Phenyl Drop-in Guard Cartridges
Offer convenience, economy and effective protection for extending column lifetime
Thermo Scientific™ Accucore™ XL C8 HPLC Columns
Improve laboratory productivity using Thermo Scientific™ Accucore™ XL C8 Columns.
Pore Size | 80 Å |
---|---|
Particle Size | 4 μm |
Carbon Load | 4% |
Stationary Phase | C8 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 9 |
Surface Area | 130 m²/g |
Max. Pressure | 8700 psi (600 bar) |
USP Type | L7 |
Thermo Scientific™ ProPac™ Elite WCX HPLC Column
This column provides consistent separations of therapeutic proteins including monoclonal antibodies, antibody drug conjugates, biosimilars and charge variants.
Pore Size | Nonporous |
---|---|
Stationary Phase | Carboxylate |
Temperature | 10°C to 60°C |
Phase | Ion Exchange |
Column Type | Ion Exchange |
Green Features | Responsibly packaged |
Max. Pressure | 4500 psi (310 bar) |
Column Format | Analytical Column |
Particle Size | 5 μm |
Packing Material | Nonporous DVB Particles with Hydrophilic Coating |
Mobile Phase Compatibility | Recommended: Goods Buffers and NaCl. Minimum 20 mM salt required. Do not rinse with pure DI H2O |
pH | 2 to 12 |
Technique | Bio-LC |
Product Line | ProPac |
Thermo Scientific™ Hypersil™ PREP HS C18 HPLC Columns
Maximize retention and loading with Hypersil PREP HS C18 prep LC reversed phase columns which offers high loading capacity and suitable for USP-L1 Applications.
Pore Size | 100 Å |
---|---|
Carbon Load | 15% |
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Spherical, Fully Porous, Ultrapure Silica |
Column Type | Reversed Phase |
pH | 2 to 9 |
Surface Area | 350 m²/g |
USP Type | L1 |
Thermo Scientific™ Accucore™ Biphenyl Reversed Phase HPLC Columns
Use this solid core column for fast and reliable separation of critical pairs and isomers.
Pore Size | 80 Å |
---|---|
Stationary Phase | Biphenyl |
Temperature | 70°C |
Phase | Reversed Phase |
For Use With | HPLC/UHPLC Instrumentation |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 130 m²/g |
Max. Pressure | 8700 psi (600 bar) |
Particle Size | 2.6 μm |
Flow Rate | 0.4 mL/min |
Carbon Load | 6% |
Packing Material | Spherical, Solid Core, Ultrapure Silica |
Diameter (Metric) | 2.1 mm |
pH | 2 to 8 |
Particle Shape | Spherical Solid Core |
Product Line | Accucore |
USP Type | L11 |
Thermo Scientific™ Hypersil™ PREP BDS Phenyl HPLC Columns
Achieve unique selectivity for aromatic and slightly polar compounds with a base-deactivated Hypersil PREP Phenyl BDS prep LC column, suitable for USP L11 applications.
Pore Size | 145 Å |
---|---|
Particle Size | 5 μm |
Carbon Load | 5% |
Stationary Phase | Phenyl (Ph) |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Spherical, Fully Porous, Base-Deactivated Silica |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 185 m²/g |
USP Type | L11 |
Thermo Scientific™ Hypercarb™ HPLC Column, 7μm
Thermo Scientific™ Hypercarb™ Columns give you 100% porous graphitic carbon for extended separation capabilities
Pore Size | 250 Å |
---|---|
Particle Size | 7 μm |
Carbon Load | 100% |
Stationary Phase | Porous Graphitic Carbon |
Temperature | 105°C |
Phase | Normal and Reversed Phase |
Packing Material | Porous Graphitic Carbon |
Column Type | Mixed Mode |
Surface Area | 120 m²/g |
USP Type | L109 |
Column Format | Analytical Column |