Chromatography Columns and Cartridges

Chromatography Columns and Cartridges
Résultats de la recherche filtrée

MilliporeSigma™ Supelco™ Chromolith™ Guard Cartridge Holder
The Chromolith™ 5-2 guard cartridge holder bioinert is suitable to connect any Chromolith™ guard cartridge to an analytical Chromolith™ HPLC column.
MilliporeSigma™ Chromolith™ Guard Cartridge Holder
Chromolith™ guard cartridge holder with 10mmL x 4.6mmID
Diamètre (métrique) interne | 4.6 mm |
---|---|
Type de colonne | Chromolith™ HPLC guard cartridge holder |
MilliporeSigma™ Chromolith™ SemiPrep Guard Cartridges
For prolonging the lifespan of Chromolith™ analytical columns
Longueur (métrique) | 10 mm |
---|---|
Type | HPLC Guard Cartridge |
Diamètre (métrique) interne | 10 mm |
Quantité | 1/Pk. |
MilliporeSigma™ Chromolith™ Prep HPLC Columns
Patented, monolithic silica technology allows ultra-fast and robust separations using standard HPLC systems
Longueur (métrique) | 100 mm |
---|---|
Type | Capillary Column |
Surface spécifique | 350 m2/g |
Quantité | 1/Pk. |
Porosité | 0.8 |
Diamètre (métrique) | 25 mm |
MilliporeSigma™ Chromolith™ SemiPrep Monolithic HPLC Columns
Patented, monolithic silica technology allows ultra-fast and robust separations using standard HPLC systems
Longueur (métrique) | 100 mm |
---|---|
Type d’USP | L1 |
Surface spécifique | 300 m²/g |
Porosité | >80% |
Diamètre (métrique) | 10 mm |
Matériau de remplissage | Silica |
Type | Column |
Température | 45°C |
Taux de carbone | 18% |
pH | 2 to 7.5 |
Quantité | 1/Pk. |
Granulométrie | Monolith |
Pression max. | 2175 psi (150 bar) |
Format de colonne | Preparative Column |
MilliporeSigma™ Chromolith™ RP Endcapped HPLC Guard Cartridges
Also popular for the protection of classical packed HPLC columns
Type | HPLC Guard Cartridge |
---|---|
Quantité | 3/Pk. |
MilliporeSigma™ Chromolith™ WP 300 Protein A HPLC Column
Chromolith™ WP 300 columns allow flow rate flexibility for much higher throughput and more solvent options for optimum selectivity.
Longueur (métrique) | 25 mm |
---|---|
Phase | Affinity Separation |
Matrice | Monolithic silica |
Température | 2 to 45°C |
Matériau | PEEK |
“End-capped” | No |
pH | 1.5 to 7.5 |
Surface spécifique | 120 m2/g |
Technique | HPLC, LC/MS |
Porosité | Monolith |
Pression max. | 200 bar |
Phase stationnaire | Protein A bonding phase |
MilliporeSigma™ Chromolith™ HighResolution RP-18 Endcapped HPLC Columns
Patented, monolithic silica technology allows ultra-fast and robust separations using standard HPLC systems
Phase | Reversed Phase |
---|---|
Type d’USP | L1 |
Surface spécifique | 250 m²/g |
Porosité | 150 Å (Mesopore Size), 1.15 μm (Macropore Size) |
Diamètre (métrique) | 4.6 mm |
Matériau de remplissage | Monolith |
Phase stationnaire | RP 18 |
Type | Column |
Taux de carbone | 18% |
“End-capped” | Yes |
Quantité | 1/Pk. |
Granulométrie | Monolith |
Type de colonne | Reversed Phase |
Format de colonne | Column |
MilliporeSigma™ Chromolith™ Performance RP-18 Endcapped HPLC Columns
Patented, monolithic silica technology allows ultra-fast and robust separations using standard HPLC systems
Longueur (métrique) | 100 mm |
---|---|
Type | Column |
Phase | Reversed Phase |
Taux de carbone | 18% |
“End-capped” | Yes |
Type d’USP | L1 |
Surface spécifique | 300 m²/g |
Quantité | 1/Pk. |
Granulométrie | Monolith |
Type de colonne | Reversed Phase |
Matériau de remplissage | Silica |
Phase stationnaire | C18 |
MilliporeSigma™ Chromolith™ WP 300 RP-18 HPLC Column
Chromolith™ WP 300 columns allow flow rate flexibility for much higher throughput and more solvent options for optimum selectivity.
Phase | Reversed Phase |
---|---|
Matrice | Monolithic silica |
Matériau | PEEK |
Type d’USP | L1 |
Surface spécifique | 300 m2/g |
Porosité | Monolith |
Diamètre (métrique) | 2 mm |
Phase stationnaire | C18 bonding phase |
Type | Column |
Température | 60°C max. |
Taux de carbone | 18% |
“End-capped” | No |
pH | 2 to 7.5 |
Technique | HPLC, LC/MS, UHPLC, UHPLC-MS |
Pression max. | 200 bar |
MilliporeSigma™ Chromolith™ Flash RP-18 Endcapped HPLC Columns
Patented, monolithic silica technology allows ultra-fast and robust separations using standard HPLC systems
Longueur (métrique) | 25 mm |
---|---|
Phase | Reversed Phase |
Type d’USP | L1 |
Surface spécifique | 300 m²/g |
Porosité | >80% |
Matériau de remplissage | Silica |
Phase stationnaire | C18 |
Type | Column |
Taux de carbone | 18% |
“End-capped” | Yes |
Quantité | 1/Pk. |
Granulométrie | Monolith |
Type de colonne | Reversed Phase |
Format de colonne | Column |
MilliporeSigma™ Chromolith™ CapRod™ RP Monolith Capillary Columns
Patented, monolithic silica technology allows ultra-fast and robust separations using standard HPLC systems
Type | Capillary Column |
---|---|
Surface spécifique | 300 m2/g |
Quantité | 1/Pk. |
MilliporeSigma™ Chromolith™ FastGradient RP-18 Endcapped HPLC Columns
Patented, monolithic silica technology allows ultra-fast and robust separations using standard HPLC systems
Longueur (métrique) | 50 mm |
---|---|
Phase | Reversed Phase |
Type d’USP | L1 |
Surface spécifique | 300 m²/g |
Porosité | >80% |
Matériau de remplissage | Silica |
Phase stationnaire | C18 |
Type | Column |
Taux de carbone | 18% |
“End-capped” | Yes |
Quantité | 1/Pk. |
Granulométrie | Monolith |
Type de colonne | Reversed Phase |
Format de colonne | Column |
MilliporeSigma™ Accessory for Chromolith™ SemiPrep Guard Cartridge
Accessory for Chromolith SemiPrep HPLC cartritdge