Learn More
Palladium(II) chloride, Premion™, 99.999% (metals basis), Pd 59.5% min
CAS: 7647-10-1 | Cl2Pd | 177.32 g/mol
Supplier: Thermo Scientific Chemicals 04308503
Description
Palladium(II) chloride is used to remove the stain present stainless steel . Its solutions are used to test the corrosion-resistance of stainless steel. It is used in carbon monoxide detectors. It is also used for cosmetic tatooing of leukomas in thecornea and in the preparation of palladium(II) iodide by reacting with potassium iodide. It is involved in the synthesis of semiconducting metal-containing polymers. It is used as a catalyst for carbonylation of organic tellurides and deamination of phenethylamines to phenyl substituted pyrroles with copper(I) as co catalyst. It plays an important role in the hydrodimerization of butadiene to form octa-2,7-dien-1-ol.
This Thermo Scientific Chemicals brand product was originally part of the Alfa Aesar product portfolio. Some documentation and label information may refer to the legacy brand. The original Alfa Aesar product / item code or SKU reference has not changed as a part of the brand transition to Thermo Scientific Chemicals.
Specifications
Palladium (II) chloride | |
7647-10-1 | |
Powder | |
(metals basis) | |
MFCD00003558 | |
palladium chloride, palladium ii chloride, palladium dichloride, palladous chloride, pdcl2, palladium 2+ chloride, palladium chloride pdcl2, enplate activator 440 | |
PIBWKRNGBLPSSY-UHFFFAOYSA-L | |
dichloropalladium | |
24290 | |
177.31 | |
Premion™ | |
Odorless |
675°C (decomposition) | |
Red to Brown | |
1 g | |
Cl2Pd | |
14,6990 | |
Soluble in cold water,organic solvents and hydrochloric acid. | |
[Cl-].[Cl-].[Pd++] | |
177.32 | |
CHEBI:53434 | |
99.999% | |
Pd 59.5% min | |
4.0 g/mL |
Chemical Identifiers
7647-10-1 | |
177.32 | |
PIBWKRNGBLPSSY-UHFFFAOYSA-L | |
24290 | |
[Cl-].[Cl-].[Pd++] |
Cl2Pd | |
MFCD00003558 | |
palladium chloride, palladium ii chloride, palladium dichloride, palladous chloride, pdcl2, palladium 2+ chloride, palladium chloride pdcl2, enplate activator 440 | |
CHEBI:53434 |
Safety and Handling
GHS H Statement
H318-H290-H317
Causes serious eye damage.
May be corrosive to metals.
May cause an allergic skin reaction.
P234-P261-P264b-P270-P272-P280-P301+P312-P302+P352-P305+P351+P338-P310-P330-P333+P313-P363-P390-P501c
H290-H302-H317-H318
DOTInformation : Hazard Class: 8; Packaging Group: III
EINECSNumber : 231-596-2
RTECSNumber : RT3500000
TSCA : Yes
Recommended Storage : Ambient temperatures
RUO – Research Use Only