missing translation for 'onlineSavingsMsg'
Learn More

METTLER TOLEDO™ InLab™ Conductivity Benchtop Probes

A selection of conductivity probes suitable for all applications.

$910.45 - $1866.67

Specifications

For Use With (Application) General conductivity measurements
Sensor Types Integrated Temperature Sensor
Connector Types Mini-DIN
View More Specs

Products 10
Catalog Number Mfr. No. Cell Constant Measurement Ranges Model Price Quantity  
Catalog Number Mfr. No. Cell Constant Measurement Ranges Model Price Quantity  
01-910-563
View Documents
METTLER TOLEDO™
51344022
0.57 cm-1 nominal 0.01 to 1000 μS/cm InLab 731-2m
Each for $1,220.05
Only null left
 
01-910-564
View Documents
METTLER TOLEDO™
51344024
0.105 cm-1 certified 0.001 to 500 μS/cm InLab 741
Each for $1,843.95
Only null left
 
01-911-443
View Documents
METTLER TOLEDO™
51344030
1.0 cm-1 nominal 0.01 to 100 mS/cm InLab 751-4mm
Each for $1,866.67
Only null left
 
01-911-444
View Documents
METTLER TOLEDO™
51344031
1.0 cm-1 nominal 0.01 to 112 mS/cm InLab 752-6mm
Each for $1,819.37
Only null left
 
01-928-132
View Documents
METTLER TOLEDO™
51302256
0.80 cm-1 nominal 0.01 to 500 μS/cm InLab 710
Each for $1,290.31
Only null left
 
01-928-133
View Documents
METTLER TOLEDO™
51302255
0.06 cm-1 nominal 0.1 to 500 μS/cm InLab 720
Each for $1,290.31
Only null left
 
01-910-562
View Documents
METTLER TOLEDO™
51344020
0.57 cm-1 nominal 0.01 to 1000 mS/cm InLab 731
Each for $910.45
Only null left
 
01-915-110
View Documents
METTLER TOLEDO™
30014092
0.57 cm-1 nominal 0.01 to 1000 mS/cm InLab 731-ISM
Each for $1,069.49
Only null left
 
01-915-111
View Documents
METTLER TOLEDO™
30014093
0.57 cm-1 nominal 0.01 to 1000 μS/cm InLab 731-2m-ISM
Each for $1,458.97
Only null left
 
01-915-112
View Documents
METTLER TOLEDO™
30014094
0.105 cm-1 certified 0.001 to 500 μS/cm InLab 741-ISM
Each for $1,712.43
Only null left
 
Description

Description

  • Required cables included for METTLER TOLEDO SevenExcellence or SevenCompact
  • Mini-DIN connects to benchtop meter; LTW connects to portable meter
  • Integrated temperature probes
  • Probes with nominal cell constants require calibration before use
  • Probes with certified cell constants are ready to use after verification step - do not calibrate

Accessories & Care

  • Store dry
  • Handle with care to avoid changing the cell constant (cell constant is a physical value)
  • Nominal cell constants require calibration with one standard (see list of standards below)
  • Certified cell constants require verification check with one standard (see list of standards below)

Standards

  • 10 μS/cm, one-time use sachets (30111141)
  • 84 μS/cm, one-time use sachets (30111140)
  • 1413 μS/cm, one-time use sachets (51302049)
  • 12.88 mS/cm, one-time use sachets (51302050)
Specifications

Specifications

General conductivity measurements
Integrated Temperature Sensor
Mini-DIN
Videos
SDS
missing translation for 'documents'

missing translation for 'documents'