missing translation for 'onlineSavingsMsg'
Learn More

Invitrogen™ Luminex™ 200™ Instrument System

The Luminex 200 Instrument System sets the standard for multiplexing, providing the ability to perform up to 100 different tests in a single reaction volume on a flow cytometry-based platform.

Supplier:  Invitrogen™ LSAPX10031

Catalog No. APX10031

Please call Customer Service at 1-800-234-7437 or send an email to help@thermofisher.com for assistance.

Explore available promotions

Description

Description

The Luminex 200 Instrument System sets the standard for multiplexing, providing the ability to perform up to 100 different tests in a single reaction volume on a flow cytometry-based platform. The Luminex 200 system is compatible with ProcartaPlex multiplex immunoassays and QuantiGene Plex multiplex gene expression assays.

Features of the Luminex system include:

  • Multiplexing: up to 80 analytes per sample using magnetic microspheres
  • Dynamic range (typical): ≥3.5 logs
  • Read time: 96-well plate in ≤45 min (up to 12,800 tests/hour)
  • Daily start-up/shut-down: ≤30 min

Available options

  • Software: extra seat licenses, Basic Security Module, 21 CFR part 11 Module, Automation Module, LIS/LIMS Module
  • Service: service contracts, IQ/OQ

Luminex xMAP technology

The open architecture of Luminex xMAP technology uses imaging, microspheres, digital signal processing, and traditional chemistry—combining proven technologies in a unique way.

Advantages of Luminex xMAP technology include:

  • Helps reduce costs and labor through multiplexing
  • Smaller sample size requirements compared to single result assays
  • Enables fast, reproducible results from favorable kinetics of liquid bead array approach
  • Broad coverage of applications, including protein expression and gene expression profiling

How Luminex xMAP technology works

Sets of magnetic microspheres are color-coded with combinations of red and infrared fluorophores. Each bead set is coated with a reagent specific to a particular bioassay, allowing the capture and detection of several specific analytes from a single sample. Optics in the compact analyzer excite the internal dyes that identify each microsphere as well as any reporter dye captured, providing quantitation of individual analytes on each microsphere. The analyzer reads many beads from each set, enabling rapid and precise results for several targets within a single sample.

Specifications

Specifications

• Luminex 200 instrument
• xMAP Sheath Fluid Sheath Delivery System
• X-Y Platform for 96-Well Plates
• xMAP Sheath Fluid
• Sample Probe Needle
• 1 L Sheath Bottle
• 1.2 L Waste Bottle
• Sample Probe Height Adjustment Kit
• Automated Maintenance Plate
• Heater Block (96-well plate)
• Documentation
• Desktop PC with Windows 10; Dell monitor, keyboard, and mouse; xPONENT Software (3 seats), and 90-day trial of Security, 21 CFR Part 11, Automation and LIS modules

Shipped separately:
• Luminex 200 Calibration Kit
• Luminex 200 Performance Verification Kit

Room Temperature
Up to 100 Tests per Hour
1 system
Product Suggestions

Product Suggestions

Videos
SDS
Documents

Documents

Promotions

Promotions

For Research Use Only. Not for use in diagnostic procedures.