missing translation for 'onlineSavingsMsg'
Learn More

CDS Empore™ 3291 Radium RAD DISK, 47 mm

Selectively bonding Ra2+ cations from sample solutions. Used for nucleid species detection. Reduce extraction time and solvent use for analytical preparation of aqueous environmental samples.

$5954.66 - $17864.02

Specifications

Bed Weight 500 mg
Format Disk
For Use With (Equipment) Vacuum Manifolds or Automated SPE Equipment
Particle Size 12 μm
Type Extraction Disk
View More Specs

Products 2
Catalog Number Mfr. No. Quantity Price Quantity  
Catalog Number Mfr. No. Quantity Price Quantity  
13-110-073
View Documents
CDS Empore™
98040500658EA
20/Pk.
Pack of 20 Each for $5,954.66
Only null left
 
13-110-074
View Documents
CDS Empore™
98040500658
60/Cs. N/A
N/A
Please call Customer Service at 1-800-234-7437 or send an email to help@thermofisher.com for assistance.
Description

Description

Empore™ RAD Disks provide an efficient alternative to conventional radiochemical sample preparation methods that use wet chemistry or packed columns.

  • Empore RAD disks provide a sample prep solution for large volume aqueous samples
  • The disk format provides a large surface area for sorbent/sample contact
  • Fast flow rates and high throughput may be realized with use of an Empore RAD disk
  • RAD disks form convenient direct counting sources when used in applicable test methods
  • Available with a variety of packings in 47 mm size
  • Approved to detect detect Radium-226 in EPA Method 903.1 and Radium-228 in EPA Method 904.0
  • Method detection limit: 0.1 pCi/L for Radium-226, and 1 pCi/L for Radium-228
Specifications

Specifications

500 mg
Vacuum Manifolds or Automated SPE Equipment
Extraction Disk
Disk
12 μm
Videos
SDS
missing translation for 'documents'

missing translation for 'documents'

To reduce the risks associated with environmental contamination, handling radiochemical materials or false negative results: Read, understand and follow all recommendations in the product MSDS and Instructions for Use.

To reduce the risks associated with radiochemical materials: Always wear the proper PPE (Personal Protection Equipment) when handling used product.

To reduce the risks associated with false negative results for radiochemicals: Always use the Empore™ Cesium Rad Disks by the expiration date.

To reduce the risks associated with environmental contamination: Dispose of used disks according to standard radiochemical procedures and regulations. Unused disks may be disposed of in accordance with standard procedure for laboratory waste.