Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only with Enhanced Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
Hauteur (impériale) | 11.5 in. |
---|---|
Certifications/Conformité | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
Précision | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
Garantie | One year from date of shipment |
Temps de réponse | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
Fréquence | 50/60 Hz |
Type de batterie | Lithium-ion |
Interface série | USB |
Profondeur (impériale) | 4 in. |
Tension | 120 V |
Largeur (impériale) | 9 in. |
Reproductibilité | ±2% at 500 ppm of methane |
Points de données | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
Composants mesurés | Most Organic and Inorganic Compounds |
Débit | 1 L/min., nominal at sample probe inlet |
Contraintes informatiques | USB port, Windows XP operating system or higher |
Limites de détection | 0.5 ppm of methane |
Concentration | 0 to 30,000 ppm (methane) |
Largeur (métrique) | 22.9 cm |
Hauteur (métrique) | 29.2 cm |
Combustible | 99.99% H2 for FID |
Autonomie en mode portable | Minimum 10 hours |
Plage de températures (métrique) | -10°C to 45°C |
Autonomie de la batterie | 10 hours at 0°C |
Plage de températures (impériale) | 14°F to 113°F |
Type de détecteur | Flame Ionization Detector (FID) |
Profondeur (métrique) | 10.2 cm |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only with Sampling Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
Hauteur (impériale) | 11.5 in. |
---|---|
Certifications/Conformité | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
Précision | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
Garantie | One year from date of shipment |
Temps de réponse | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
Fréquence | 50/60 Hz |
Type de batterie | Lithium-ion |
Interface série | USB |
Profondeur (impériale) | 4 in. |
Tension | 120 V |
Largeur (impériale) | 9 in. |
Reproductibilité | ±2% at 500 ppm of methane |
Points de données | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
Composants mesurés | Most Organic and Inorganic Compounds |
Débit | 1 L/min., nominal at sample probe inlet |
Contraintes informatiques | USB port, Windows XP operating system or higher |
Limites de détection | 0.5 ppm of methane |
Concentration | 0 to 30,000 ppm (methane) |
Largeur (métrique) | 22.9 cm |
Hauteur (métrique) | 29.2 cm |
Combustible | 99.99% H2 for FID |
Autonomie en mode portable | Minimum 10 hours |
Plage de températures (métrique) | -10°C to 45°C |
Autonomie de la batterie | 10 hours at 0°C |
Plage de températures (impériale) | 14°F to 113°F |
Type de détecteur | Flame Ionization Detector (FID) |
Profondeur (métrique) | 10.2 cm |
MSA™ ALTAIR™ 4XR Multigas Detector
Provides real-time incident awareness when paired with the ALTAIRALTAIR™ Connect app via a Bluetooth™ wireless connection. MSA™ ALTAIR™ 4XR Multigas Detector is the toughest 4-gas monitor when outfitted with rapid-response XCell™ sensors.
Blackline Safety™ G7c Cellular-Connected Safety Monitor with Multi-Gas/Twin Tox Sensor Cartridge, North America
Wireless connectivity ensures that each G7c is remotely configurable and firmware updates are automatic. G7c supports three cartridge types that provide a choice of gas detection options. Everything is completely customizable to meet the needs of every industry, application and scenario
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Sampling Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
Hauteur (impériale) | 11.5 in. |
---|---|
Certifications/Conformité | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
Précision | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
Garantie | One year from date of shipment |
Temps de réponse | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
Fréquence | 50/60 Hz |
Type de batterie | Lithium-ion |
Interface série | USB |
Profondeur (impériale) | 4 in. |
Tension | 120 V |
Largeur (impériale) | 9 in. |
Reproductibilité | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
Points de données | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
Composants mesurés | Most Organic and Inorganic Compounds |
Débit | 1 L/min., nominal at sample probe inlet |
Contraintes informatiques | USB port, Windows XP operating system or higher |
Limites de détection | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
Largeur (métrique) | 22.9 cm |
Hauteur (métrique) | 29.2 cm |
Combustible | 99.99% H2 for FID |
Autonomie en mode portable | Minimum 10 hours |
Plage de températures (métrique) | -10°C to 45°C |
Autonomie de la batterie | 10 hours at 0°C |
Plage de températures (impériale) | 14°F to 113°F |
Type de détecteur | Dual Configured with FID and PID |
Profondeur (métrique) | 10.2 cm |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Enhanced & Sampling Probes
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
Hauteur (impériale) | 11.5 in. |
---|---|
Certifications/Conformité | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
Précision | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
Garantie | One year from date of shipment |
Temps de réponse | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
Fréquence | 50/60 Hz |
Type de batterie | Lithium-ion |
Interface série | USB |
Profondeur (impériale) | 4 in. |
Tension | 120 V |
Largeur (impériale) | 9 in. |
Reproductibilité | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
Points de données | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
Composants mesurés | Most Organic and Inorganic Compounds |
Débit | 1 L/min., nominal at sample probe inlet |
Contraintes informatiques | USB port, Windows XP operating system or higher |
Limites de détection | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
Largeur (métrique) | 22.9 cm |
Hauteur (métrique) | 29.2 cm |
Combustible | 99.99% H2 for FID |
Autonomie en mode portable | Minimum 10 hours |
Plage de températures (métrique) | -10°C to 45°C |
Autonomie de la batterie | 10 hours at 0°C |
Plage de températures (impériale) | 14°F to 113°F |
Type de détecteur | Dual Configured with FID and PID |
Profondeur (métrique) | 10.2 cm |
Blackline Safety™ G7c Cellular-Connected Safety Monitor with Multi-Gas Sensor Cartridge, North America
Wireless connectivity ensures that each G7c is remotely configurable and firmware updates are automatic. G7c supports three cartridge types that provide a choice of gas detection options. Everything is completely customizable to meet the needs of every industry, application and scenario
Blackline Safety™ G7x Satellite-Connected Safety Monitor with Multi-Gas/Twin Tox Sensor Cartridge, North America
Wireless connectivity ensures that each G7x is remotely configurable and firmware updates are automatic. G7x supports three cartridge types that provide a choice of gas detection options. Everything is completely customizable to meet the needs of every industry, application and scenario
Fréquence | 900 MHz |
---|---|
Type | Multigas Cartridge |
Blackline Safety™ G7c Cellular-Connected Safety Monitor with Multi-Gas Pump Sensor Cartridge, North America
Wireless connectivity ensures that each G7c is remotely configurable and firmware updates are automatic. G7c supports three cartridge types that provide a choice of gas detection options. Everything is completely customizable to meet the needs of every industry, application and scenario
Type | Multigas Cartridge |
---|
Blackline Safety™ G7x Satellite-Connected Safety Monitor with Multi-Gas Pump Sensor Cartridge, North America
Wireless connectivity ensures that each G7x is remotely configurable and firmware updates are automatic. G7x supports three cartridge types that provide a choice of gas detection options. Everything is completely customizable to meet the needs of every industry, application and scenario
Type | Multigas Cartridge |
---|---|
Description | G7x 900MHz |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only (No Probes)
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
Hauteur (impériale) | 11.5 in. |
---|---|
Certifications/Conformité | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
Précision | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
Garantie | One year from date of shipment |
Temps de réponse | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
Fréquence | 50/60 Hz |
Type de batterie | Lithium-ion |
Interface série | USB |
Profondeur (impériale) | 4 in. |
Tension | 120 V |
Largeur (impériale) | 9 in. |
Reproductibilité | ±2% at 500 ppm of methane |
Points de données | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
Composants mesurés | Most Organic and Inorganic Compounds |
Débit | 1 L/min., nominal at sample probe inlet |
Contraintes informatiques | USB port, Windows XP operating system or higher |
Limites de détection | 0.5 ppm of methane |
Concentration | 0 to 30,000 ppm (methane) |
Largeur (métrique) | 22.9 cm |
Hauteur (métrique) | 29.2 cm |
Combustible | 99.99% H2 for FID |
Autonomie en mode portable | Minimum 10 hours |
Plage de températures (métrique) | -10°C to 45°C |
Autonomie de la batterie | 10 hours at 0°C |
Plage de températures (impériale) | 14°F to 113°F |
Type de détecteur | Flame Ionization Detector (FID) |
Profondeur (métrique) | 10.2 cm |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only with Enhanced & Sampling Probes
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
Hauteur (impériale) | 11.5 in. |
---|---|
Certifications/Conformité | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
Précision | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
Garantie | One year from date of shipment |
Temps de réponse | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
Fréquence | 50/60 Hz |
Type de batterie | Lithium-ion |
Interface série | USB |
Profondeur (impériale) | 4 in. |
Tension | 120 V |
Largeur (impériale) | 9 in. |
Reproductibilité | ±2% at 500 ppm of methane |
Points de données | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
Composants mesurés | Most Organic and Inorganic Compounds |
Débit | 1 L/min., nominal at sample probe inlet |
Contraintes informatiques | USB port, Windows XP operating system or higher |
Limites de détection | 0.5 ppm of methane |
Concentration | 0 to 30,000 ppm (methane) |
Largeur (métrique) | 22.9 cm |
Hauteur (métrique) | 29.2 cm |
Combustible | 99.99% H2 for FID |
Autonomie en mode portable | Minimum 10 hours |
Plage de températures (métrique) | -10°C to 45°C |
Autonomie de la batterie | 10 hours at 0°C |
Plage de températures (impériale) | 14°F to 113°F |
Type de détecteur | Flame Ionization Detector (FID) |
Profondeur (métrique) | 10.2 cm |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Enhanced Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
Hauteur (impériale) | 11.5 in. |
---|---|
Certifications/Conformité | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
Précision | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
Garantie | One year from date of shipment |
Temps de réponse | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
Fréquence | 50/60 Hz |
Type de batterie | Lithium-ion |
Interface série | USB |
Profondeur (impériale) | 4 in. |
Tension | 120 V |
Largeur (impériale) | 9 in. |
Reproductibilité | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
Points de données | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
Composants mesurés | Most Organic and Inorganic Compounds |
Débit | 1 L/min., nominal at sample probe inlet |
Contraintes informatiques | USB port, Windows XP operating system or higher |
Limites de détection | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
Largeur (métrique) | 22.9 cm |
Hauteur (métrique) | 29.2 cm |
Combustible | 99.99% H2 for FID |
Autonomie en mode portable | Minimum 10 hours |
Plage de températures (métrique) | -10°C to 45°C |
Autonomie de la batterie | 10 hours at 0°C |
Plage de températures (impériale) | 14°F to 113°F |
Type de détecteur | Dual Configured with FID and PID |
Profondeur (métrique) | 10.2 cm |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID (No Probes)
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
Hauteur (impériale) | 11.5 in. |
---|---|
Certifications/Conformité | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
Précision | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
Garantie | One year from date of shipment |
Temps de réponse | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
Fréquence | 50/60 Hz |
Type de batterie | Lithium-ion |
Interface série | USB |
Profondeur (impériale) | 4 in. |
Tension | 120 V |
Largeur (impériale) | 9 in. |
Reproductibilité | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
Points de données | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
Composants mesurés | Most Organic and Inorganic Compounds |
Débit | 1 L/min., nominal at sample probe inlet |
Contraintes informatiques | USB port, Windows XP operating system or higher |
Limites de détection | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
Largeur (métrique) | 22.9 cm |
Hauteur (métrique) | 29.2 cm |
Combustible | 99.99% H2 for FID |
Autonomie en mode portable | Minimum 10 hours |
Plage de températures (métrique) | -10°C to 45°C |
Autonomie de la batterie | 10 hours at 0°C |
Plage de températures (impériale) | 14°F to 113°F |
Type de détecteur | Dual Configured with FID and PID |
Profondeur (métrique) | 10.2 cm |