Pre-packed columns, cartridges, and guard columns for separation of biomolecules and organic/inorganic analytes; includes normal/reversed phase HPLC, UHPLC, LC-MS, HILIC, mixed-mode, ion exchange, ligand exchange, and affinity column formats.
Manufactured with a proprietary process and subjected to stringent quality control procedures, these LC Columns are used for the appropriate counter-ion to meet application requirements.
TSKgel GMHXL Mixed-Bed Columns are packed with a mixture of rigid, polymer beads, varying in average pore size. Ideal for the analysis of organic-soluble industrial polymers.
Packed with rigid, porous, polymer beads which show minimal shrinkage or swelling in different solvent systems. Used for the separation of polymers that are soluble in polar organic solvents. Exclusion Limit (DMF): Polyethylene Oxide > 4 x 107 Da.
Packed with rigid, porous, polymer beads which show minimal shrinkage or swelling in different solvent systems. Used for the separation of polymers that are soluble in polar organic solvents. Exclusion Limit (DMF): Polyethylene Oxide 400,000 Da.
Packed with rigid, porous, polymer beads which show minimal shrinkage or swelling in different solvent systems. Used for the separation of polymers that are soluble in polar organic solvents. Exclusion Limit (DMF): Polyethylene Oxide 2,000 Da.
Packed with rigid, porous, polymer beads which show minimal shrinkage or swelling in different solvent systems. Used for the separation of polymers that are soluble in polar organic solvents. Exclusion Limit (DMF): Polyethylene Oxide 4,000,000 Da.
Packed with rigid, porous, polymer beads which show minimal shrinkage or swelling in different solvent systems. Used for the separation of polymers that are soluble in polar organic solvents. Exclusion Limit (DMF): Polyethylene Oxide 60,000 Da.
Packed with rigid, porous polymer beads which show minimal shrinkage or swelling in different solvent systems. Columns are best used for the separation of polymers that are soluble in polar organic solvents.
TSKgel MultiporeHxl-M Columns are packed with rigid, polymer beads that have a large pore size distribution within each particle. For the analysis of organic-soluble industrial polymers.
Packed with rigid, porous polymer beads which show minimal shrinkage or swelling in different solvent systems. Columns are best used for the separation of polymers that are soluble in polar organic solvents.
Packed with rigid, porous polymer beads which show minimal shrinkage or swelling in different solvent systems. Columns are best used for the separation of polymers that are soluble in polar organic solvents.